IECEx ATEX Certified Explosion proof LED Lights - Zone 1 Zone 2 Hazardous Area Lighting

CESP Zone 1 Zone 2 hazardous location LED lights are in accordance with International Protection Techniques (Equipment Protection Levels), including IEC/EN 60079-0 (General Requirement), IEC/EN 60079-1 (Flameproof Enclosure), IEC/EN 60079-7 (Increased Safety), IEC/EN 60079-11 (Intrinsic Safety), IEC/EN 60079-15 (Type of Protection), IEC/EN 60079-18, IEC/EN 60079-28, IEC/EN 60079-31. If you are not sure about the Classified of your lighting application environment, please contact our technical department for the solution.
 

For Zone 1 Zone 2, Zone 21 Zone 22 hazardous area led lighting, 20W - 200W, 130lm/W,aluminum alloy + 8mm tempered glass, multi-installation for different projects, such as light tower, canopy light, marine grade.

Flameproof enclosure, Ex db op is IIC T6 Gb, Zone 1 & Zone 21 with explosive gas atmosphere, Zone 21 and Zone22 with explosive dust atmosphere, 10mm temered glass, 7J impact resistance,up to 26000lm.

Flameproof enclosure, Ex db op is IIC T6 Gb, IP68 protection grade, tempered glass 10mm, withstand impacts up to 10J, 2 foot and 4 foot Length, 50Watt- 240Watt, 130lm/W light efficacy.

Zone 1 & Zone 21, 1ft, 2ft, 3ft, 4ft length can be selected, replace the traditional explosion-proof three-proof lamp, explosion-proof fluorescent tube, anti-corrosion, anti-glare, anti-drop, competitive price.

Flameproof LED hand lamp for Zone 1 & Zone 21 hazardous areas, 10mm tempered glass, pass the multi-angle drop test, 10W, 20W, 30W Power, can be connected to the cable, emergency power box.

The CES-EX-SF series explosion-proof ceiling lamp has a strong shell, with features such as impact resistance, vibration resistance, and corrosion resistance. It can be used in hazardous environments of Zone 1&21, Zone 2&22.

CES-EX-JX Series is your go-to solution for illuminating hazardous Zone 1 and Zone 21 areas. With ATEX approval, these Explosion-proof LED Flood Lights offer unbeatable safety standards.

Discover the pinnacle of safety and illumination with our CES-EX-GBX Series Explosion-proof LED High Bay Lights. Designed for hazardous Zone 1 and Zone 21 areas, these lights boast ATEX approval, ensuring the highest safety standards.

GB-02 explosion-proof lights are made of alloy aluminum and tempered glass, with shock resistance and anti-vibration performance. The luminaires have passed the ATEX IECEx standards test, from 30W to 80W for hazardous area lighting.

LN-02 explosion-proof lights obtained an IECEx ATEX certificate, it's safe for the Zone 1 and Zone 2 hazardous locations. The copper-free aluminum alloy body is powder-coated to increase durability and beautiful appearance, are able to withstand violent shaking and shock resistance.

an innovative line of LED hazardous area lighting products, specifically designed for use in potentially explosive atmospheres (Zone 1/21 & 2/22) within harsh industrial settings such as coal mines and oil & gas facilities.

Explosion-proof safety exit lamps are for personnel evacuation, and fire operations to provide lighting fire emergency lamps! It usually uses an external power supply, when the power automatically switches to the battery power state!

 

Applications:
• Wastewater treatment, oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases are present.
• Applies to hazardous locations of Class I, Division 2 with explosive gas atmosphere.
• Applies to marine locations, non-recessed outside type (salt water).

Warning

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING 40°C;
  • FOR SUPPLY CONNECTION, USE WIRES RATED FOR AT LEAST90°C;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.

UL for marine locations:

  • OUTSIDE TYPE or OUTSIDE TYPE (SALT WATER);
 

Features

  • Industry-leading efficacy: 120 - 140LM/W
  • -40°C to +55°C Ambient operating temperature
  • Wide optics for uniform illumination
  • Entry Size: NPT 3/4”-14 ;
  • Housing –Aluminum alloy (ADC12 );
  • Lens –tempered glass
  • Beam angle: 108°, 120°
  • Dimension: 400x400x169mm
  • Weight: 22kg

Parameters

  • Power: 240W / 300W / 370W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • LED Driver: Meanwell HLG series

Certificate & Standard

Have certified CES-J fixtures with the NEC and CEC standards for hazardous location and environments

  • Class I, Division 2, Groups A, B, C and D
  • T-Class: T5
  • Damp and wet locations
  • Certificate No:E475887
  • US: UL 844; UL 1598A;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0;

Mounting

Versatile mounting options:

  • Universal installation
  • Mounting Angle:0°to ±90°;

Applications:
• Wastewater treatment, oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases are present.
• Applies to hazardous locations of Class I, Division 2 with explosive gas atmosphere.
• Applies to marine locations, non-recessed outside type (salt water).

Warning

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING 40°C;
  • FOR SUPPLY CONNECTION, USE WIRES RATED FOR AT LEAST90°C;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.

UL for marine locations:

  • OUTSIDE TYPE or OUTSIDE TYPE (SALT WATER);
 

Features

  • Industry-leading efficacy: up to 120 LPW
  • -40°C to +55°C Ambient operating temperature
  • Wide optics for uniform illumination
  • Entry Size: NPT 3/4”-14 ;
  • Housing –Aluminum alloy (ADC12 );
  • Lens –tempered glass
  • Beam angle: 108°, 120°
  • Dimension: 400x400x169mm
  • Weight: 10.5kg

Parameters

  • Power: Max 185W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 110 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • LED Driver: Meanwell HLG series

Certificate & Standard

Have certified CES-J fixtures with the NEC and CEC standards for hazardous location and environments

  • Class I, Division 2, Groups A, B, C and D
  • T-Class: T5
  • Damp and wet locations
  • Certificate No:E475887
  • US: UL 844; UL 1598A;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0;

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Pole mount
  • Wall Mount
  • Mounting Angle:0°to ±90°;

Applications:
• Wastewater treatment, oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases are present.
• Applies to hazardous locations of Class I, Division 2 with explosive gas atmosphere.
• Applies to marine locations, non-recessed outside type (salt water).

Warning

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING 40°C;
  • FOR SUPPLY CONNECTION, USE WIRES RATED FOR AT LEAST90°C;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.

UL for marine locations:

  • OUTSIDE TYPE or OUTSIDE TYPE (SALT WATER);
 

Features

  • Industry-leading efficacy: up to 140lm/W
  • -40°C to +55°C Ambient operating temperature
  • Wide optics for uniform illumination
  • Fixture warranty
  • Entry Size: NPT 3/4”-14 ;
  • Housing –Aluminum alloy (ADC12 );
  • Lens –tempered glass
  • Beam angle: 108°, 120°
  • Dimension: 300x300x165mm
  • Weight: 7.5kg

Parameters

  • Power: 60W / 80W / 100W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 110 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • LED Driver: Meanwell HLG series

Certificate & Standard

Have certified CES-J fixtures with the NEC and CEC standards for hazardous location and environments

  • Class I, Division 2, Groups A, B, C and D
  • T-Class: T6
  • Damp and wet locations
  • Certificate No:E475887
  • US: UL 844; UL 1598A;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0;

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Pole mount
  • Wall Mount
  • Mounting Angle:0°to ±90°;

Applications:
Wastewater treatment, oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases are present.
Applies to hazardous locations of Class I, Division 2 with explosive gas atmosphere.
Applies to marine locations, non-recessed outside type (salt water).

Warning

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING 40°C;
  • FOR SUPPLY CONNECTION, USE WIRES RATED FOR AT LEAST90°C;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.

UL for marine locations:

  • OUTSIDE TYPE or OUTSIDE TYPE (SALT WATER);
 

Features

  • Industry-leading efficacy: up to 120 LPW
  • -40°C to +55°C Ambient operating temperature
  •  Wide optics for uniform illumination
  •  5 years warranty
  •  Entry Size: NPT 3/4”-14 ;
  •  Housing –Aluminum alloy (ADC12 );
  •  Lens –tempered glass
  •  Beam angle: 108°, 120°
  •  Dimension: 200x200x147mm
  • Weight: 4kg

Parameters

  •  Power: Max 40W
  •  Input voltage: AC100-240/277V, 50/60Hz
  •  Power factor: 0.97
  •  Light efficacy: 110 - 140lm/W
  •  CCT: 3000K/4000K/5000K/5700K/6500K
  •  LEDs: 3030
  •  LED Driver: Meanwell HLG series

Certificate & Standard

Have certified CES-J fixtures with the NEC and CEC standards for hazardous location and environments

  • Class I, Division 2, Groups A, B, C and D
  • T-Class: T6
  • Damp and wet locations
  • Certificate No:E475887
  • US: UL 844; UL 1598A;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0;

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Pole mount
  • Wall Mount
  • Mounting Angle:0°to ±90°;

Explosion Proof LED Flood Light - Zone 1 Zone 21 - 120W/150W/180W 200W - U Bracket Mount

 

Applications:
• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN 60079-0: 2013 ; EN 60079-7: 2015 ; EN 60079-18: 2015 ; EN 60079-28: 2015 ; EN 60079-31:2014;

Warning

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose.
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 95℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally.

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -20°C to +40°C Ambient operating temperature
  • Amounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 90°, 108°

Parameters

  • Power:120W/150W/180W/200W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Lumen flux: 14400lm/18000lm/22200lm
  • CCT: 2700K - 6500K (Optional)
  • LEDs: 3030
  • LED Driver: Meanwell HLG series
  • Dimension: 400mm x 400mm x 169(248)mm
  • Weight: 10.5KG

Certificate & Standard

Have certified CES-J fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • EX II 2G Ex eb mb op is IIC T4 Gb
  • EX II 2D Ex op is tb IIIC T(95°C) Db
  • IP66
  • Certify No:IEP 19ATEX 0714
IECEx:
  • Ex ec IIC T4 Gc
  • IP66
  • Certify No:IECEx UL 18.0046

Special order

  • Special Orders- Requirements
    Contact us for special requirements
    Tel: +86-755-83509822
    Fax: +86-755-83509868
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

 Applications:

• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN 60079-0: 2013 ; EN 60079-7: 2015 ; EN 60079-18: 2015 ; EN 60079-28: 2015 ; EN 60079-31:2014;

Warning

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose.
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 95℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally.

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -20°C to +40°C Ambient operating temperature
  • Amounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 90°, 108°

Parameters

  • Power:60W/80W/100W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Lumen flux: 7200lm / 9600lm / 12000lm
  • CCT: 2700K - 6500K (Optional)
  • LEDs: 3030
  • LED Driver: Meanwell HLG series
  • Dimension: 300mm x300mm x 165(251)mm
  • Weight: 7.5KG

Certificate & Standard

Have certified CES-J fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • EX II 2G Ex eb mb op is IIC T4 Gb
  • EX II 2D Ex op is tb IIIC (T95°C) Db
  • IP66
  • Certify No:IEP 19ATEX 0714
IECEx:
  • Ex ec IIC T4 Gc
  • IP66
  • Certify No:IECEx UL 18.0046

Special order

  • Special Orders- Requirements
    Contact us for special requirements
    Tel: +86-755-83509822
    Fax: +86-755-83509868
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

Applications:

• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN 60079-0: 2013 ; EN 60079-7: 2015 ; EN 60079-18: 2015 ; EN 60079-28: 2015 ; EN 60079-31:2014;

 

Warning

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose.
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 95℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally.

 

Mounting:

Fix 2 M10 screws on the wall according to the distance between the holes of the bracket. Install the bracket on the screws and then fasten it with the nut. Fix the position of the lamp Place the lamp cord into the pole; connect the wire to local power supply (AC100-277V).

explosion proof floodlight installation

explosion proof floodlight M25 entry size

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -20°C to +40°C Ambient operating temperature
  • Amounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 90°, 108°

Parameters

  •  Power:20W/30W/40W
  •  Input voltage: AC100-240/277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 2400lm / 3600lm / 4800lm
  •  CCT: 2700K - 6500K (Optional)
  •  LEDs: 3030
  •  LED Driver: Meanwell HLG series
  •  Dimension: 200mm*200mm*147mm
  •  Weight: 4KG

Certificate & Standard

Have certified CES-J fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • EX II 2G Ex eb mb op is IIC T4 Gb
  • EX II 2D Ex op is tb IIIC T(95°C) Db
  • IP66
  • Certify No.:IEP 19ATEX 0714
IECEx:
  • Ex ec IIC T4 Gc
  • IP66
  • Certify No:IECEx UL 18.0046

Special order

  • Contact us for special requirements
    Tel: +86-755-83509822
    Fax: +86-755-83509868
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.