CES-SC Series Explosion Proof Hand Lamp / Drop Light comes complete with 10 meters (according to your requirement can be more longer) of explosion proof cord and an inline transformer that steps down 120V AC to 24V AC or DC for powering the lamp. The hand lamp is designed to provide an effective low voltage lighting solution for operators requiring a versatile source of illumination.

This hazardous location hand lamp is 10W, 20W, 30W power optional, UL Listed Class 1 Division 1 Groups A, B, C and D, is ideal for general work task lighting in hazardous locations requiring explosion proof protection.

 

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING __55__ °C (_131 °F);
  • MIN 90°C (194°F) SUPPLY CONDUCTORS;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -40°C to +50°CCAmbient operating temperature
  • Swivel hook for hanging and hands free operation
  • Prevent drop damage
  • 5 years warranty
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass (10mm)
  • Beam angle:360°

Parameters

  •  Power: 10W / 20W / 30W
  •  Input voltage: 100-240Vac; Frequency: 50/60Hz;
  • Output voltage: 24Vdc
  •  Lumen flux: 1300LM/2600LM/3900LM
  •  CCT: 6500K (Optional)
  •  LEDs: 3030
  •  LED Driver: High Efficiency LED Driver
  •  Dimension: Φ101.5 x 516.5 mm
  •  Weight: 2.4KG

Certificate & Standard

Have certified CES-SC fixtures with the North American UL844 standards for hazardous location and environments.

NEC/CEC:

  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 1, Groups E, F and G
  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 2, Groups F and G
  • Class III
  • T-Class: T6 / T80°C
  • Damp and wet locations
  • Paint spray rated
  • Certificate No:E475887

 

Standard:

  • US: UL 844; UL 153;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No.250.4

Send Your Iquiry

Make sure you enter all the required information, indicated by an asterisk (*). HTML code is not allowed.